Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1955 1
1958 1
1966 1
1968 2
1971 2
1972 3
1973 4
1974 2
1975 2
1976 2
1977 1
1978 1
1979 3
1980 4
1981 3
1982 1
1984 1
1985 2
1987 2
1988 1
1989 4
1991 2
1992 1
1993 4
1994 1
1995 4
1996 2
1997 3
1999 5
2000 2
2001 5
2003 1
2004 3
2005 1
2006 3
2007 5
2008 9
2009 4
2010 6
2011 4
2012 6
2013 6
2014 6
2015 9
2016 6
2017 6
2018 7
2019 5
2020 5
2021 4
2022 3
2023 2
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

154 results

Results by year

Filters applied: . Clear all
Page 1
Simulating Arbitrary Electrode Reversals in Standard 12-lead ECG.
Krasteva V, Jekova I, Schmid R. Krasteva V, et al. Sensors (Basel). 2019 Jul 1;19(13):2920. doi: 10.3390/s19132920. Sensors (Basel). 2019. PMID: 31266252 Free PMC article.
Electrode reversal errors in standard 12-lead electrocardiograms (ECG) can produce significant ECG changes and, in turn, misleading diagnoses. ...The simulation model of ECG electrode swaps and the resultant WCT potential change is derived in th
Electrode reversal errors in standard 12-lead electrocardiograms (ECG) can produce significant ECG changes and, in turn
Armband Sensors Location Assessment for Left Arm-ECG Bipolar Leads Waveform Components Discovery Tendencies around the MUAC Line.
Escalona O, Mukhtar S, McEneaney D, Finlay D. Escalona O, et al. Sensors (Basel). 2022 Sep 24;22(19):7240. doi: 10.3390/s22197240. Sensors (Basel). 2022. PMID: 36236340 Free PMC article.
However, there is a paucity of understanding on the number and best bipolar ECG electrode pairs axial orientation around the left mid-upper arm circumference (MUAC) for such devices. This study addresses the question on the best axial orientation of ECG bipol …
However, there is a paucity of understanding on the number and best bipolar ECG electrode pairs axial orientation around the l …
Electrode Equivalence for Use in Bioimpedance Spectroscopy Assessment of Lymphedema.
Svensson BJ, Dylke ES, Ward LC, Kilbreath SL. Svensson BJ, et al. Lymphat Res Biol. 2019 Feb;17(1):51-59. doi: 10.1089/lrb.2018.0002. Epub 2018 Oct 6. Lymphat Res Biol. 2019. PMID: 30300090
METHODS AND RESULTS: Two types of Ag/AgCl electrodes were studied: instrument-specific bioimpedance electrodes (bioimpedance) and single tab ECG electrodes (cardiac). Six areas of investigation were addressed: intrinsic electrode resistance; …
METHODS AND RESULTS: Two types of Ag/AgCl electrodes were studied: instrument-specific bioimpedance electrodes (bioimpedance) …
Electrode Size and Placement for Surface EMG Bipolar Detection from the Brachioradialis Muscle: A Scoping Review.
Merlo A, Bò MC, Campanini I. Merlo A, et al. Sensors (Basel). 2021 Nov 3;21(21):7322. doi: 10.3390/s21217322. Sensors (Basel). 2021. PMID: 34770627 Free PMC article. Review.
We conducted a scoping review of the main databases to explore available guidelines of electrode placement on BRD and to map the electrode configurations used and authors' awareness on the issues of crosstalk. ...One hundred and six studies (79%) did not even addres …
We conducted a scoping review of the main databases to explore available guidelines of electrode placement on BRD and to map the e
Noninvasive Electrocardiography in the Perinatal Mouse.
Fitzsimons LA, Brewer VL, Forrester J, Moran AM, Tucker KL. Fitzsimons LA, et al. J Vis Exp. 2020 Jun 12;(160). doi: 10.3791/61074. J Vis Exp. 2020. PMID: 32597855
Electrocardiography (ECG) has long been relied upon as an effective and reliable method of assessing cardiovascular (and cardiopulmonary) function in both human and animal models of disease. Individual heart rate, rhythm, and regularity, combined with quantitative p
Electrocardiography (ECG) has long been relied upon as an effective and reliable method of assessing cardiovascular (and cardi
Deep Arm/Ear-ECG Image Learning for Highly Wearable Biometric Human Identification.
Zhang Q, Zhou D. Zhang Q, et al. Ann Biomed Eng. 2018 Jan;46(1):122-134. doi: 10.1007/s10439-017-1944-z. Epub 2017 Oct 13. Ann Biomed Eng. 2018. PMID: 29030801
Specifically, to achieve a super wearability, we suggest situating all the ECG electrodes on the left upper-arm, or behind the ears, and successfully obtain weak but distinguishable ECG waveforms. ...Experimental results on two acquired datasets using our wea …
Specifically, to achieve a super wearability, we suggest situating all the ECG electrodes on the left upper-arm, or behind the …
Modified limb lead placement for rapid ECG.
Fesmire FM. Fesmire FM. Am J Emerg Med. 1995 Sep;13(5):603-4. doi: 10.1016/0735-6757(95)90181-7. Am J Emerg Med. 1995. PMID: 7662065 No abstract available.
A new electrode placement method for obtaining 12-lead ECGs.
Khan GM. Khan GM. Open Heart. 2015 Jun 9;2(1):e000226. doi: 10.1136/openhrt-2014-000226. eCollection 2015. Open Heart. 2015. PMID: 26082845 Free PMC article.
Studies show that the standard wrist-ankle placement method may produce poor quality ECGs. Factors including limb movement, tremor, anxiety, cold extremities cause artefacts (distortions of the baseline and ECG waveforms). ...A total of 1112 patients received standa …
Studies show that the standard wrist-ankle placement method may produce poor quality ECGs. Factors including limb movement, tremor, anxiety, …
First description of the Burmeister porpoise (Phocoena spinipinnis) electrocardiogram.
Dassis M, De León C, Díaz A, Faiella A, Olguin J, Saubidet A, Rodríguez DH, Castro EF. Dassis M, et al. J Exp Zool A Ecol Integr Physiol. 2022 Oct;337(8):795-801. doi: 10.1002/jez.2641. Epub 2022 Jul 14. J Exp Zool A Ecol Integr Physiol. 2022. PMID: 35833489
For ECG recordings, the animal was removed from its pool on a stretcher under constant veterinary supervision. A traditional six-lead system in the frontal plane was used, with the typical four "extremities" electrodes positioned bilaterally. ECGs were readab …
For ECG recordings, the animal was removed from its pool on a stretcher under constant veterinary supervision. A traditional six-lead …
Does modifying electrode placement of the 12 lead ECG matter in healthy subjects?
Sheppard JP, Barker TA, Ranasinghe AM, Clutton-Brock TH, Frenneaux MP, Parkes MJ. Sheppard JP, et al. Int J Cardiol. 2011 Oct 20;152(2):184-91. doi: 10.1016/j.ijcard.2010.07.013. Epub 2010 Aug 10. Int J Cardiol. 2011. PMID: 20701990
BACKGROUND: Limb electrodes for the 12 lead ECG are routinely placed on the torso during exercise stress testing or when limbs are clinically inaccessible. It is unclear whether such electrode modification produces ECG changes in healthy male or female …
BACKGROUND: Limb electrodes for the 12 lead ECG are routinely placed on the torso during exercise stress testing or when limbs …
154 results